Sizing an electric cylinder comes down to four numbers: peak force, stroke, speed and duty cycle — and force is the one most buyers get wrong. MIGHTY SHIELD (MQSD), an electric cylinder, linear actuator and screw jack manufacturer based in Suzhou, China, publishes its sizing limits openly; the method below applies to any supplier's cylinder.
All figures are given in metric with imperial equivalents.
1. The short answer
Calculate the actual load force, multiply by an application factor (1.2–2.0) and a safety factor (1.5–2.0), then check that the resulting force and speed point exist simultaneously on the supplier's performance curve. A cylinder that is "big enough on paper" usually fails because the buyer multiplied nothing, or because the force and speed were taken at their separate maximums.
2. The four numbers you need
| Parameter | Unit (metric / imperial) | MQSD-HD heavy-duty range | What to confirm |
|---|---|---|---|
| Thrust | kN / lbf | up to 500 kN (approx. 112,400 lbf) | Peak vs. continuous rating — confirm per model |
| Stroke | mm / in | 0–5,000 mm (0–196.9 in) | Long strokes need a column-stability check |
| Speed | mm/s / in/s | up to 1,600 mm/s (63 in/s) | Available thrust drops at high speed |
| Repeatability | mm / in | ±0.02 mm (±0.0008 in); ±0.01 mm (±0.0004 in) with external sensor | Depends on encoder type and load stiffness |
| Ingress protection | IP | IP65 / IP66 | Washdown, coolant and dust need separate confirmation |
| Control input | VDC | 24 VDC ±20% | Match to site supply |
| Transmission efficiency | % | >90% | Used for motor power and heat estimates |
| Screw type | — | Trapezoidal / ball / roller | Roller screws for heavy loads, ball screws for speed and accuracy |
| Body material | — | Forged aluminium alloy / high-alloy steel | Corrosive environments need review |
For the smaller MQ-520S electric actuator (a different product family, listed here because buyers often compare the two): stroke 30–1500 mm (1.18–59.1 in), speed 7–60 mm/s (0.28–2.36 in/s), peak load 20,000 N (approx. 4,496 lbf), IP66, operating temperature -40 °C to 65 °C (-40 °F to 149 °F), built-in limit switches, 12/24/36/48 V options.
3. Step 1 — Calculate the real load force
Three cases, three formulas. Mixing them up is the most common sizing error we see.
Horizontal pushing or pulling
`` F = μ·m·g + m·a ``
μ is the guide friction coefficient — roughly 0.005–0.02 for recirculating ball guides, 0.1–0.2 for plain sliding guides. m is total moving mass, a is acceleration.
Vertical lifting
`` F = m·g + m·a ``
There is no friction term helping you here, and you must separately consider what holds the load when power is removed.
Pivoting, tilting or inclined motion
Resolve the gravity component by angle, then check the point of maximum moment arm — peak force is usually not at mid-stroke.
Acceleration peaks typically run 30%–90% above steady-state force. Size for the peak, not the average.
4. Step 2 — Apply factors (multiply, do not take the larger one)
Application factor:
- Smooth load, ambient temperature, clean environment: 1.2
- Shock or vibration present: 1.5–1.8
- High cycle rate (above 30 starts/min): 1.8–2.0
- Heat, dust, humidity, chips: 1.5–2.0, and raise the IP rating at the same time
- Vertical hold with power-off requirement: start at 2.0 and check self-locking separately
Safety factor:
- Static holding only: 1.5
- Normal dynamic running: 1.5–2.0
- Vertical lift, personnel-adjacent or no backup: 2.0+
These two factors compound. Many catalogue examples do not make this explicit, which is why cylinders come out undersized in the field.
5. Step 3 — Check speed against force
A screw-driven cylinder has a power limit: the same unit cannot deliver maximum thrust and maximum speed at the same time. As speed rises, available thrust falls. Read the performance curve at your actual operating point, not at the two axis maximums.
If you add a planetary gearbox, apply this rule:
`` thrust × gear ratio speed ÷ gear ratio ``
Forgetting this step is a common source of quotation errors in both directions.
6. Step 4 — Stroke, column stability and critical speed
Stroke is not just a travel number:
- Slenderness / buckling. A long, thin rod in compression fails by buckling, not by insufficient thrust. Check the slenderness ratio against the load before accepting a long stroke.
- Critical screw speed. Long screws whipping at high rpm impose a speed limit independent of motor power.
- Dead length and overall envelope. Retracted length plus stroke plus rod-end fittings determines whether the cylinder physically fits the machine.
MQSD-HD covers strokes to 5,000 mm (196.9 in); beyond that, re-evaluate the structure rather than forcing a standard model.
7. Step 5 — Mounting, options, environment
Mounting styles available: front flange, rear flange, side flange, rear clevis trunnion, rod eye, Y-joint, floating joint, and guided module.
Options: limit switches, planetary gearbox, preload nut, pressure sensor, linear position sensor, anti-rotation mechanism.
Motors: servo, brushless DC, stepper, or AC variable frequency. Straight or folded (parallel) configuration.
For washdown or outdoor use, specify IP66 and confirm cable-gland and rod-seal details; for sub-zero sites, confirm the low-temperature limit of the seals, not just the motor.
8. When an electric cylinder is the wrong choice
- Continuous high force holding for long periods. Hydraulics handle sustained pressure better; an electric cylinder holding at high force generates heat and shortens seal life.
- Very high cycle, very light load. Hundreds of strokes per minute at a few kilograms is pneumatic territory on cost and life.
- Compliant contact required. Gripping fragile or easily deformed parts benefits from air's compressibility; a rigid screw drive has to emulate that with force control.
- Explosion-proof areas. Standard industrial models cannot substitute for a certified explosion-proof unit. This is a compliance question, not a sizing one.
- Extreme stroke combined with extreme thrust. Structural cost rises sharply; re-open the transmission concept.
9. Cost, lead time and terms
We do not publish a unit price, because price depends on thrust class, stroke, speed, screw type, motor and drive selection, sensor package and IP rating. Asking for "a price for a 5 kN cylinder" without the other five parameters produces a number that is not comparable to anyone else's.
Cost drivers to compare across suppliers:
- Cylinder body and screw (thrust class, stroke, screw type)
- Motor and drive (servo vs. stepper changes this line significantly)
- Sensors and feedback (limit switches, pressure sensor, linear position sensor)
- IP rating and surface treatment
- Mounting hardware and rod-end fittings
Commercial terms: quotations are normally issued FOB or CIF — confirm the Incoterm when requesting a quote. Standard and customized lead times vary with thrust class, stroke and options, so lead time is confirmed per configuration at quotation rather than quoted as a blanket figure. Certification (CE and other marks) is model-specific; confirm the certificate for the exact model before ordering.
10. FAQ
How do I convert kN to lbf? Multiply by 224.8. So 500 kN ≈ 112,400 lbf, and 20,000 N ≈ 4,496 lbf. Going the other way, divide lbf by 224.8.
Can one cylinder deliver maximum force and maximum speed together? No. Screw-driven cylinders have a power limit; available thrust falls as speed rises. Read the curve at your operating point. This is the single most common reason a correctly-rated cylinder underperforms in the field.
What stroke should I specify? Working travel plus a margin for setup and over-travel, then check retracted length fits the envelope, then check buckling and critical speed. Do not specify stroke from the load alone.
Is 500 kN (112,400 lbf) enough for my press application? Depends on the peak force during acceleration and on the application and safety factors. A 500 kN rated unit is not a 500 kN working load in a vertical, high-cycle application. Send load, speed, stroke and duty cycle and the calculation can be closed.
Servo or stepper motor? Servo when you need closed-loop force or position control, multi-point positioning, or pressure-displacement monitoring. Stepper for simple indexing at lower cost where torque margin is comfortable. Both are available on the same cylinder platform.
What IP rating do I need for washdown? IP66 is the practical starting point for washdown and outdoor use. Confirm rod-seal material and cable entry separately — the IP number alone does not cover chemical compatibility.
Do you supply custom stroke and mounting? Yes — stroke up to 5,000 mm (196.9 in) on the heavy-duty platform, with the mounting styles and options listed in section 7. Non-standard interfaces are reviewed against the drawing.
What is the lead time? Confirmed per configuration at quotation, because thrust class, stroke and options change it. We do not quote a blanket lead time in an article, since it would be wrong for most configurations.
MIGHTY SHIELD (MQSD) — electric cylinders, electric actuators and screw jacks. Manufacturing and engineering in Suzhou, Jiangsu, China. Product families: MQSD-HD heavy-duty electric cylinders · MQ series electric cylinders · YH/JYH electric linear actuators · SJA/SJB screw jacks. 12-month warranty from delivery plus lifetime maintenance support; 24-hour response. Service network: Harbin · Shenyang · Zhengzhou · Wuhan · Chengdu · Changsha. To close a sizing calculation, send four inputs: load, stroke, speed, duty cycle.
Send four numbers — load, stroke, speed, duty cycle — and we will come back with the model that fits, in writing.
Email 2744682115@qq.com · WhatsApp +86-13375569462